An advanced coating thickness gauge with an external, interchangeable F/N probe for enhanced flexibility and access to difficult areas. It provides accurate thickness readings for paint, powder, and other coatings on both magnetic and non-magnetic substrates. The external probe offers a flexible solution for complex geometries and continuous monitoring, ensuring complete and compliant coverage.


Advanced dual-mode gauge with integrated statistics and data storage for professional reporting.

  • Similar to the entry-level model but with added features like internal memory, statistical analysis of readings (e.g., Min, Max, Avg), and user-defined calibration points.
  • This makes it ideal for professional coating inspectors requiring detailed quality reports and traceability, meeting stringent industry standards.
  • The product consists of the advanced dual-mode gauge, a comprehensive set of calibration standards, and a carrying case.
  • The external probe improves measurement stability and accessibility in confined or awkward spaces.

Top Features & Benefits

  • F&N model for both ferrous (Magnetic Induction) and non-ferrous (Eddy Current) substrates.
  • Features an external/separate probe for hard-to-reach areas and continuous scanning.
  • High measurement precision and resolution (down to 0.1 micron).
  • Large memory capacity for storing thousands of readings and batches.
  • Statistical analysis (Min/Max/Avg/Standard Deviation) for quality reporting.
  • Multiple calibration modes including zero-point and two-point calibration.
  • Automatic substrate identification (Fe or NFe).

Primary Uses & Functions

An advanced gauge used to measure the thickness of non-magnetic coatings on magnetic substrates (Fe) and non-conductive coatings on non-magnetic substrates (NFe). Its primary function is recording and analyzing data for Quality Control (QC) documentation.


Real-World Applications

  • Measuring Non-Magnetic Coating Thickness (e.g., paint, zinc, chrome) on Ferrous (F) substrates.
  • Measuring Non-Conductive Coating Thickness (e.g., powder, plastic, anodizing) on Non-Ferrous (N) substrates (e.g., aluminum, brass).
  • Quality control in painting, powder coating, and plating industries.
  • Corrosion protection monitoring for industrial assets.

Industry Solutions

  • Oil & Gas (Corrosion protection coating checks)
  • Petrochemical
  • Railway
  • Automotive (Body shop and paint thickness inspection)
  • Mining
  • Power Generation
  • Wind & Solar
  • Manufacturing (QC for surface treatments)

Technical Specifications

Principle Magnetic Induction (F) and Eddy Current (N)
Substrates Ferrous metals (F) and Non-ferrous metals (N)
Measuring Range 0 to 1250 micron (0 to 50 mil) (Typical), probe dependent
Probe External F/N Probe (Separate and interchangeable)
Accuracy plus or minus (3%H+1 micron) (Where H is the thickness reading)
Resolution 0.1 micron (0 to 100 micron) / 1 micron (over 100 micron)
Data Storage Internal memory for readings and batches, data output (RS232/USB)
Display Backlit LCD, large size with statistical readout
Operating Modes Single, Continuous, and Statistical (Average, Min, Max, Standard Deviation)

 


Compatibility

  • Advanced Ferrous/Non-Ferrous (FN) coating thickness gauge with enhanced measurement modes and data storage.
  • A precision handheld instrument for paint, plating, and non-conductive layers.
  • Compatible with a variety of specialized external probes for different applications.

What’s In The Box?

  • TG 8826 FN Coating Thickness Gauge unit (advanced).
  • External F/N Probe and connecting cable.
  • Set of certified calibration foils (shims).
  • Zero test substrates (ferrous and non-ferrous).
  • USB cable and software for data transfer.
  • Batteries and robust carrying case.

Also Known As

Paint Thickness Meter, Ferrous Non-Ferrous Gauge, Dual Purpose Coating, External Probe Thickness Gauge, FN Gauge


FAQ: TG 8826 FN – Coating Thickness Gauge

What do “F” and “N” signify in the model number?

“F” indicates the gauge can measure coatings on Ferrous (magnetic) substrates using the magnetic induction principle. “N” indicates it can measure coatings on Non-ferrous (non-magnetic) substrates using the Eddy Current principle.

What is the primary use of this gauge?

It is used to measure the thickness of non-conductive coatings (paint, powder, plastic) on metal substrates.

**Errors and omissions excepted (E&OE)

Get a Quote

YOUR ONE STOP NDT EQUIPMENT SUPPLIER!

Need Assistance? Contact Us.


Phone: +27 16 423 7731
Visit Us:
Vision 21 Industrial Park, Steel Road,
Peacehaven, Vereeniging, South Africa, 1939

Related Products

TG 8826 FN – COATING THICKNESS GAUGE

Capture and manage large volumes of coating thickness data across various substrates. The TG 8826 FN Coating Thickness Gauge is a dual-function instrument with integrated data logging for ferrous and non-ferrous substrates. It streamlines large-scale inspection by storing thousands of readings, ensuring traceable quality control of protective coatings and efficient reporting on surface preparation. Supplier: Huatec