Start typing to explore our solutions!
Find products, categories, news, and more.
The Flammable Gas Sensor Payload by Flyability is a type of sensor built to add an additional layer of safety to Elios 3 drone operations. It is used to detect and measure the concentration of combustible gases in the air, which may ignite or explode if exposed to an ignition source.
This Payload should not replace standard gas detection procedures and is not built as a tool to search for gas concentrations. If any level of gas is detected you should immediately exit the area with the drone and shut off the drone. Supplier: Flyability SA
An external sensor module payload designed to be mounted on the Elios 3 inspection drone. It is used to detect and measure the presence of toxic or combustible gases within confined, hazardous spaces. This payload provides a critical safety and environmental monitoring solution for pre-entry atmospheric testing and leak detection.
Important Safety Notice on the Use of the Flammable Gas Sensor
This drone is not safe for use in environments with known flammable gas. Do not operate in areas with potential gas presence.
The drone’s airflow can alter gas concentration, affecting sensor accuracy. Readings should be considered approximate.
The gas sensor is a safety aid, not a precise gas leak detection or quantification tool.
The sensor does not replace standard safety procedures. Always follow proper protocols for flying in potentially hazardous environments.
By mounting and using the Flammable Gas Sensor by Flyability, you accept these limitations and full responsibility for the drone’s operation and any resulting consequences. Flyability is not liable for any damage, injury, or loss incurred during use.
A sensor accessory for the Elios 3 drone used for detecting and mapping dangerous gases (e.g., CO, H2S) during indoor and confined space inspections.
| Sensor manufacturer | NevadaNano |
| Sensor type | Molecular Property Spectrometer™ (MPS™) Flammable Gas Sensor 5.0 |
| Calibration | No calibration required (factory calibrated) |
| Response time (T90) | < 20 seconds¹ |
| Operating temperature | 0 ºC to 50 ºC (32 °F to 122 °F) |
| Humidity range | 0% to 95%¹ |
| Pressure range | 80 to 120 kPa¹ |
| Airflow velocity | 7 m/s¹ |
| Bump Test flow rate | Min: 150 mL/min¹ Max: 500 mL/min¹ |
| Keep alive | Max: 3 min |
| Ingress protection | Splash and dust resistant design |
| Weight | 45.5 g, 1.60 oz |
1. Value subject to change
| Payloads compatibility | Rev6 and Rev7 LiDAR Payloads, RAD Payload, UT Payload |
| Flight time while hovering¹ |
|
1. Value subject to change
| Gas | Formula | Class | Range [%LEL] | % Vol. at 100 %LEL¹ (ISO 10156) | MPS Accuracy 0-50 %LEL¹ (ISO 10156) | % Vol. at 100 %LEL¹ (IEC 60079-20-1) | MPS Accuracy 0-50 %LEL¹ (IEC 60079-20-1) |
|---|---|---|---|---|---|---|---|
| Butane | C₄H₁₀ | 4 | 0-100 | 1.8 %VOL | ±5 %LEL | 1.4 %VOL | ±5 %LEL |
| Ethane | C₂H₆ | 4 | 0-100 | 3.0 %VOL | ±5 %LEL | 2.4 %VOL | ±5 %LEL |
| Hydrogen | H₂ | 1 | 0-100 | 4.0 %VOL | ±5 %LEL | 4.0 %VOL | ±7 %LEL |
| Isobutane | HC(CH₃)₃ | 4 | 0-100 | 1.8 %VOL | ±5 %LEL | 1.3 %VOL | ±9 %LEL |
| Isobutylene | C₄H₈ | 4 | 0-100 | 1.8 %VOL | ±5 %LEL | 1.8 %VOL | ±5 %LEL |
| Isopropanol | C₃H₈O | 4 | 0-100 | 2.0 %VOL | ±10 %LEL | 2.0 %VOL | +20 %LEL |
| Methane | CH₄ | 3 | 0-100 | 5.0 %VOL | ±3 %LEL | 4.4 %VOL | ±3 %LEL |
| MEK | C₄H₈O | 5 | 0-100 | 1.4 %VOL | ±5 %LEL | 1.5 %VOL | +16 %LEL |
| Pentane | C₅H₁₂ | 5 | 0-100 | 1.5 %VOL | ±5 %LEL | 1.1 %VOL | ±6 %LEL |
| Propane | C₃H₈ | 4 | 0-100 | 2.1 %VOL | ±6 %LEL | 1.7 %VOL | ±8 %LEL |
| Propylene | C₃H₆ | 4 | 0-100 | 2.4 %VOL | ±5 %LEL | 2.0 %VOL | ±5 %LEL |
| Acetone | C₃H₆O | 5 | 0-100 | 2.5 %VOL | +20 %LEL | 2.5 %VOL | +24 %LEL |
| Ethylene | C₂H₄ | 4 | 0-100 | 2.7 %VOL | −12 %LEL | 2.3 %VOL | −14 %LEL |
| Heptane | C₇H₁₆ | 5 | 0-100 | 1.1 %VOL | ±12 %LEL | 0.85 %VOL | ±15 %LEL |
| Octane | C₈H₁₈ | 6 | 0-100 | 1.0 %VOL | ±12 %LEL | 0.8 %VOL | ±15 %LEL |
| Styrene | C₈H₈ | 6 | 0-100 | 1.1 %VOL | -20 %LEL | 1.0 %VOL | −17 %LEL |
| Toluene | C₇H₈ | 6 | 0-100 | 1.2 %VOL | ±12 %LEL | 1.0 %VOL | ±13 %LEL |
| Xylene | C₈H₁₀ | 6 | 0-100 | 1.1 %VOL | ±12 %LEL | 1.0 %VOL | ±13 %LEL |
The Flammable Gas Sensor is factory calibrated to the accuracy levels shown below, with no need for further recalibration or adjustment.
It also detects other gases not listed in the table, including 1-butene, acetylene, ammonia, cyclohexane, decane, diesel, dimethyl carbonate, ethanol, gasoline vapors, hexane, and methanol.
However, the sensor does not provide LEL accuracy for these gases and may over- or under-report, so special precautions should be taken when using the MPS to detect them.
1. Accuracy is guaranteed for methane and hydrogen across the full environmental range. For other gases, accuracy typically meets published tolerances under standard
conditions of 20°C and 50% RH, and when oxygen is present in the air. Additionally, the airflow generated by the drone’s propellers can disperse gas concentrations around the sensor and interfere with the accuracy of
gas measurements. For more precise readings, it is recommended to land the drone and turn off the propellers.
Flammable Gas Sensor (1)
Sensor mount (1)
Bump test tool (1)
Silicon tube 400 mm (1)
Dust filter for gas sensor (3)
Transport case (1)
SOFTWARE:
Cockpit integration (Included)
Methane Detection UAV, Aerial Leak Detector, Remote Gas Monitor
This payload allows the Elios 3 drone to perform remote detection and mapping of hazardous or combustible gases within confined spaces or dangerous environments.
It can be configured to detect various gases, including Methane (CH4), Carbon Monoxide (CO), and other flammable or toxic industrial gases.
**Errors and omissions excepted (E&OE)
Our team of Non-Destructive Testing experts is ready to help you find the perfect equipment and solutions tailored to your specific industry requirements.