100m roll of 19-strand Nickel cold leg compensating wire. Used in thermocouple circuits to maintain signal accuracy across temperature gradients. Supplier: Incertech
Scroll to view all images
This 100-meter roll contains 19-strand Nickel Cold Leg Compensating Wire. This wire is a crucial component in industrial thermocouple circuits, specifically designed to serve as the ‘cold leg’ (negative conductor) in compensating cable runs. It is engineered to maintain signal accuracy by minimizing thermal signal error along the extension from the thermocouple’s hot junction (Supplier: Incertech).
In a thermocouple circuit, the cold leg (usually negative) requires a compensating alloy to maintain the integrity of the millivolt signal over distance, preventing errors that would be introduced by standard copper wire. This high-quality, 19-stranded nickel wire provides a flexible and reliable solution for the cold side of the circuit, offering the necessary thermoelectric properties to ensure that temperature measurements for PWHT remain precise.
Manufacturing or repairing K-Type thermocouple compensating extension cables, used to connect thermocouples to monitoring and control instruments.
| Characteristic | Details |
|---|---|
| Material | Compensating Nickel Alloy |
| Function | Cold Leg (Negative) Conductor |
| Construction | 19 Stranded |
| Roll Length | 100 meters |
| Supplier SKU | Wire-NCW0297 |
Used in conjunction with the corresponding compensating alloy for the positive leg (e.g., Chromel compensating material) to form a complete Type K extension cable.
1 x Roll of 19 Strand Nickel Cold Leg Compensating Wire (100m).
Thermocouple Negative Wire, Compensating Nickel Wire, Cold Junction Wire, Extension Lead Conductor.
The compensating alloy is necessary to ensure the extension cable’s internal wires have the same thermal electric properties as the thermocouple’s wires, which prevents a secondary thermal EMF (voltage) from being unintentionally generated along the cable run.
No, the compensating properties are specifically tailored to the K-Type system. Using this wire with other thermocouple types will introduce significant temperature errors.
The stranded construction is primarily for flexibility and mechanical robustness. Signal quality is determined by the alloy composition, which maintains the required thermoelectric properties.
**Errors and omissions excepted (E&OE)