Detailed Overview

This is a handheld coating thickness gauge featuring an integrated F (ferrous) probe and N (non-ferrous) probe. It automatically measures the thickness of non-magnetic coatings on steel (F) or non-conductive coatings on non-ferrous metals (N). The F/N combination provides a fast, universal solution for verifying coating thickness for corrosion protection and quality control.


Entry-level combined gauge for measuring coating thickness on both ferrous and non-ferrous metals.

  • This dual-purpose gauge automatically identifies the substrate (magnetic steel or non-magnetic metal) and uses the appropriate method (Magnetic Induction or Eddy Current) to measure the thickness of paint, coatings, or galvanization.
  • It is an essential QC tool for surface preparation and coating application, ensuring compliance with specifications like ISO and ASTM.
  • The package includes the gauge unit, a set of calibration foils, and a zero substrate block.
  • The integrated probe design allows for quick, single-handed operation.

Top Features & Benefits

  • Coating thickness gauge measuring both Ferrous (F) and Non-Ferrous (N) substrates.
  • Uses magnetic induction (F) and eddy current (N) principles within a single, integrated sensor.
  • Features an integrated probe for robust, one-piece portability.
  • Automatic substrate recognition for fast and error-free measurements.
  • High measurement precision with resolution down to 0.1 micron.
  • Digital LCD display with backlight for clear readings.

Primary Uses & Functions

A gauge used to measure the thickness of non-magnetic coatings on magnetic substrates (Fe) and non-conductive coatings on non-magnetic substrates (NFe). Its primary function is to provide rapid, non-destructive coating thickness verification in the field.


Real-World Applications

  1. Coating thickness gauge TG-8825F can measure the thickness of non-magnetic coating layers (aluminium, chrome, copper, ename1, rubber, paint) on magnetic substrate (steel, iron, alloy and magnetic stainless steel)
  2. Coating thickness gauge TG-8825N can measure the thickness of non-conductive coating layers (enamel, rubber, paint, vanish, plastic anodic oxide layer) covered on non-ferrous substrate (aluminium, brass, zinc, tin and non-magnetic stainless steel)

Industry Solutions

  • Oil & Gas (Corrosion coating checks)
  • Petrochemical
  • Railway
  • Automotive (Used car inspection, body repair, manufacturing QC)
  • Mining
  • Power Generation
  • Wind & Solar
  • Manufacturing (QC for surface finish and plating)

Technical Specifications

Principle Magnetic Induction (F) and Eddy Current (N)
Substrates Ferrous metals (F) and Non-ferrous metals (N)
Measuring Range 0 to 1250 micron (0 to 50 mil) (Typical), probe dependent
Accuracy plus or minus (3%H+1 micron) (Where H is the thickness reading)
Resolution 0.1 micron (0 to 100 micron) / 1 micron (over 100 micron)
Probe Integrated F/N probe (Combi Probe)
Display Digital LCD with backlight
Zero Calibration Simple zero-point calibration on bare substrate

 


Compatibility

  • Combined Ferrous (F) and Non-Ferrous (N) probe for measuring non-magnetic coatings on magnetic substrates (F) and non-conductive coatings on non-magnetic metal substrates (N).
  • A digital, handheld gauge used across automotive and industrial sectors for quick, general-purpose coating thickness assessment.

What’s In The Box?

  • TG 8825 FN Coating Thickness Gauge main unit.
  • Standard F/N combi probe (integrated).
  • Zero test plates (steel and aluminum).
  • Calibration foils (shims) set.
  • Carry pouch and batteries.
  • User manual.

Also Known As

Paint Thickness Meter, Ferrous Non-Ferrous Gauge, Dual Purpose Coating, Combi Coating Gauge, FN Meter


FAQ: TG 8825 FN – Coating Thickness Gauge

How does the TG 8825 FN differ from the TG 8826 FN?

The 8825 is likely the standard or base model, while the 8826 may include advanced features like datalogging, high-temperature probes, or a different measurement range.

**Errors and omissions excepted (E&OE)

Get a Quote

YOUR ONE STOP NDT EQUIPMENT SUPPLIER!

Need Assistance? Contact Us.


Phone: +27 16 423 7731
Visit Us:
Vision 21 Industrial Park, Steel Road,
Peacehaven, Vereeniging, South Africa, 1939

Related Products

TG 8825 FN – COATING THICKNESS GAUGE

Measure coating thickness accurately on both ferrous and non-ferrous substrates with one device. The TG 8825 FN Coating Thickness Gauge is a dual-function instrument that automatically detects the substrate material and uses the appropriate method (Magnetic Induction for Fe and Eddy Current for non-Fe). It ensures quality control of protective coatings to prevent premature corrosion and ensure long-term asset integrity. Supplier: Huatec