Key Specifications of the A456CFNFBI1 Variant

  • Model Tier (Model B): The A456CFNFBI1 falls under the Model B category, which provides essential measurement features and on-screen statistics.

  • Probe Type (Integral): This variant features an internal probe built directly into the gauge for streamlined, one-handed operation.

  • Substrate Compatibility (FNF): It is equipped to measure coating thickness across both Ferrous (F) and Non-Ferrous (N) substrate types.

Physical Dimensions & Build

  • Dimensions: The gauge measures 141 x 73 x 37 mm (5.55 x 2.87 x 1.46″).

  • Weight: The integral model weighs 156 g (5.5 oz), which includes the weight of the batteries.

  • Power Supply: It operates using 2 x AA batteries, and rechargeable batteries can also be used.

  • Operating Environment: The device functions within an operating temperature range of -10 to 50°C (14 to 122°F).

Display & Interface

  • Screen: The gauge features a colour screen for clear data visibility.

  • Auto-Rotation: The screen settings include an Auto Display Rotation feature to improve readability at various viewing angles.

  • Multifunction Keys: Menu navigation is managed via multifunction softkeys.

  • Units of Measurement: The gauge can be configured to display thickness readings in µm, mm, mils, or inches.

Calibration Methods (Model B)

The A456CFNFBI1 supports several calibration methods to ensure accuracy across different surfaces:

  • Zero Calibration: A 1-point calibration method that is ideal for smooth surfaces.

  • Smooth Calibration: A 2-point calibration where the user selects a suitable calibration foil along with an uncoated smooth substrate.

  • Rough / 2 Point Calibration: This is the ideal calibration method for rough or profiled substrates.

  • Security: A calibration lock can be enabled using a four-digit PIN code to secure calibration settings from accidental adjustment.

Data Output & Statistics

As a Model B device, it retains robust statistical tracking capabilities without requiring advanced batching.

  • On-Screen Statistics: The gauge calculates and displays the Number of Readings, Mean, Lowest Reading, Highest Reading, Standard Deviation, and Coefficient of Variation.

  • Bar Graph: A visual bar graph provides an analogue representation of the thickness value, along with the highest, lowest, and average readings.

  • PC Connectivity: The gauge features a USB data output socket. All gauges can transmit their readings to a PC for archiving and report generation.

**Errors and omissions excepted (E&OE)

Gammatec Contact Block

Need Assistance or Looking for Something Else?

Our team of Non-Destructive Testing experts is ready to help you find the perfect equipment and solutions tailored to your specific industry requirements.

Add Product to Quote

Product Page Auto-Datasheet Widget

Technical Documentation

RELATED FAQ'S

Gammatec Mobile Floating Menu