Input your X-ray tube parameters, material, and film setup to calculate estimated exposure times. Use the dual timers for single or double film techniques.
Spacer
Typically +10-20% time if superimposed
| Tube | Setup | Time | Action |
|---|
Unlike Gamma, X-ray calculates required Exposure (mA·min) using empirical base values, adjusting for distance and material attenuation before dividing by tube current.
Time = [ E_base * F * (SFD/1000)² * 2^(x/HVL) ] / mA
Understanding the electrical variables of the X-ray tube allows fine-tuning of contrast and exposure speed.
Unlike Gamma isotopes which have discrete energies, X-ray HVL depends on the applied Tube Voltage (kV). These are standard educational approximations.
| Material | 100 kV | 150 kV | 200 kV | 250 kV | 300 kV |
|---|---|---|---|---|---|
| Steel | 1.0 | 1.5 | 2.5 | 3.2 | 4.0 |
| Aluminum | 4.0 | 6.0 | 9.0 | 12.0 | 16.0 |
| Class | Agfa Structurix | Carestream Industrex | Fujifilm IX | Multiplier |
|---|---|---|---|---|
| C1-C2 | D3 | M100 | IX25 | 1.50 |
| C3 | D4 | MX125 | IX50 | 1.00 (Base) |
| C4 | D5 | T200 | IX80 | 0.60 |
| C5 | D7 | AA400 | IX100 | 0.35 |
| C6 | D8 | HS800 | IX150 | 0.15 |
Relative exposure required to hit specific optical densities.