GammaTec Navigation
Your One Stop NDT Equipment Supplier
Operating Hours: Mon–Thu 07:00–17:00 | Fri 07:00–16:00
GammaTec Logo
NDT Solutions
View All NDT Solutions
Conventional Ultrasonic
Advanced Ultrasonic
Acoustic Emission
Guided Wave
Conventional Radiography
Digital Radiography
Electromagnetic
Material Analysers
Hardness Testing
Leak Detection
Post-Weld Heat Treatment
Drones & Robotics
Visual Inspection
Wire Rope Testing
Isotopes
About Us
Company Overview About Us Testimonials Partners Compliance & Docs POPIA Documentation
News & Events
Resources & Training
Documentation & Support Calibrations & Repairs Brochures & Data Sheets Safety Data Sheets Training & Tools Training Hub FAQ Company & Portals Careers CMS Portal
NDT Tools
Contact Us

RT Conversion Tool

  • Home
  • RT Conversion Tool
NDT Tools Quick Links

RT Conversion Tool ? Radiographic Testing Converter
Accurately convert between standard and SI units for radioactivity, radiation dose, exposure, and length used in the NDT industry.

? Select Formula
Choose the specific unit conversion required for your equipment or reporting.
? Input Value
Enter the numerical value you wish to convert. The calculation updates automatically.
Result
Please enter a value
Disclaimer: Conversion factors are based on accepted international scientific standards. Errors and omissions excepted.

NDT Radiation Metrics Guide

Radioactivity (Activity)

Measures the physical rate at which a radioactive isotope decays (emits radiation) from the source.

  • Ci (Curie): Traditional unit.
  • Bq (Becquerel): SI unit (1 decay per sec).
  • Conversions: 1 Ci = 37 GBq = 0.037 TBq

Biological Equivalent Dose

Measures the biological effect and risk of radiation damage on human tissue. Used for personal dosimetry.

  • Rem (Roentgen Eq. Man): Traditional unit.
  • Sv (Sievert): SI unit.
  • Conversions: 1 Sv = 100 Rem

Absorbed Dose

Measures the physical amount of energy deposited by ionizing radiation into a mass (such as an object or tissue).

  • Rad: Traditional unit.
  • Gy (Gray): SI unit (Joules/kg).
  • Conversions: 1 Gy = 100 Rad

Radiation Exposure

Measures the amount of ionization produced purely in the air by X-rays and gamma rays.

  • R (Roentgen): Traditional unit.
  • C/kg: SI unit (Coulombs per kilogram).